A detector reading can contain both a source signal and a baseline. A change in the source scales its contribution—not necessarily the whole reading.

01 · THE IDEA

Subtract the baseline, scale the signal, then add the appropriate baseline back.

New raw = new background + factor × (old raw − old background)

Use this model only when the detector is linear and the background is additive. If background changes between conditions, use each condition’s own background. For a point source without attenuation and with fixed detector geometry, signal is proportional to source power divided by distance squared.

Raw versus corrected

A raw reading of 250 with a background of 10 contains a corrected signal of 240. Doubling that source contribution gives 480, then adding the same background gives a new raw reading of 490.

Distance is squared

Doubling distance from an isotropic point source reduces its signal to one-quarter. An additive detector background does not fall to one-quarter unless the model says it changes too.

Know what is missing

If background is unknown or changes without measurement, a raw-reading ratio generally cannot determine the source-signal ratio. Do not assume that the baseline is zero.

CHANGE ONE PART OF THE MODEL

Keep the background separate

At baseline power and distance d, raw = 250 counts/s and background = 10 counts/s. The detector is linear, the point source is isotropic, and there is no attenuation.

Source power
Distance
Corrected signal240 counts/s
Fixed background10 counts/s
Raw reading250 counts/s

10 + (250 − 10) × 1 / 1² = 250 counts/s

The baseline is added once after the physical scaling is applied.

02 · WORKED EXAMPLES

Follow the setup, then the numbers

1. Change distance and power together

At distance d, raw signal is 250 counts/s with a constant background of 10 counts/s. Double both source power and distance, keeping the detector linear.

  1. Corrected original signal = 250 − 10 = 240 counts/s.
  2. Scaling factor = 2 / 2² = 1/2.
  3. New corrected signal = 120 counts/s.
  4. New raw signal = 120 + 10 = 130 counts/s.

Carry this forward: Scale 240, not 250. Source power and distance act on the source contribution.

2. Compare two conditions with different baselines

Condition A has raw = 180 and background = 30. Condition B has raw = 340 and background = 40, in the same units.

  1. Corrected A = 180 − 30 = 150.
  2. Corrected B = 340 − 40 = 300.
  3. Signal ratio B/A = 300/150 = 2.

Carry this forward: The raw ratio 340/180 would mix source change with baseline change.

03 · TRY IT IN DIFFERENT FORMS

Practice in different forms

0 of 4 checked

For each question, identify the requested quantity and write the setup before calculating. Use a hint if needed, then choose an answer to see the explanation.

Untimed learning practice. These responses stay on this page and reset when you leave or reload; they do not change your test results.

QUESTION 1 / 4 · Across subjects

Double the source contribution

A linear detector reads 160 counts/s, including a fixed background of 40 counts/s. The source contribution doubles. What is the new raw reading?

Choose one answer
1 of 4

TAKE INTO A FRESH PASSAGE

Your setup checklist

  1. Identify whether the question asks for raw or corrected signal.
  2. Subtract the baseline appropriate to each condition.
  3. Apply source-power and distance factors to the corrected signal.
  4. Restore background only if the requested answer is a raw reading.

Before calculating, explain what each term represents and what the requested answer would mean.